Building construction
Model: WDZC-BYJR
Rated voltage (kV): 0.3/0.5, 0.45/0.75
Main use: Fixed cloth wires for buildings, electrical, switches, and other applications with flame retardant performance requirements.
Model: WDZC-BYJR
Rated voltage (kV): 0.3/0.5, 0.45/0.75
Main use: Fixed cloth wires for buildings, electrical, switches, and other applications with flame retardant performance requirements.
Model: WDZC-BYJ
Rated voltage (kV): 0.3/0.5, 0.45/0.75
Main use: Fixed cloth wires for buildings, electrical, switches, and other applications with flame retardant performance requirements.
Model: FZ-VV, FZ-N-VV, FZ-Z (A, B, C) N-VV
Rated voltage (kV): 0.6/1KV
Main use: High insulation strength, with certain water and air tightness at the branch cable joint of encapsulated injection molding. Construction and installation are simpler and more convenient under environmental conditions such as horizontal, pre embedded, overhead, tunnel, airport runway, port terminal, mine, and modern industrial plant.
Models: FZ-YJV, FZ-N-YJV, FZ-Z (A, B, C) - YJV, FZ-Z (A, B, C) N-YJV, FZ-WDZ (A, B, C) - YJY, FZ-WDZ (A, B, C) N-YJY
Rated voltage (kV): 0.6/1KV
Main use: With high insulation strength, the connection body of the injection molded branch joint and the outer insulation sheath of the cable are tightly bonded together, providing excellent water and air tightness. Construction and installation are simpler and more convenient under environmental conditions such as horizontal, pre embedded, overhead, tunnel, airport runway, port terminal, mine, and modern industrial plant.
Model: WDZ (A, B, C) - YJLH63
Rated voltage (kV): 0.6/1
Main use: Interlocking armor, lightweight, easy to install, can be laid in dry or humid environments, and can be exposed indoors using brackets, brackets, ladders, or cable clamps; Cable trenches, tunnels, or direct burial can be used outdoors to withstand certain mechanical external forces.
Model: YJLH62
Rated voltage (kV): 0.6/1
Main use: Interlocking armor, lightweight, easy to install, can be laid in dry or humid environments, and can be exposed indoors using brackets, brackets, ladders, or cable clamps; Cable trenches, tunnels, or direct burial can be used outdoors to withstand certain mechanical external forces.
Model: YJLH60
Rated voltage (kV): 0.6/1
Main use: Interlocking armor, lightweight, easy to install, able to withstand certain mechanical external forces, can be laid in non humid indoor, tunnel, and fixed on brackets, saving bridge or conduit costs.
Model: BBTRZ
Rated voltage (kV): 0.6/1
Main use: Used as a power transmission line for fire protection systems in high-rise buildings, underground buildings, hospitals, schools, business centers, department stores, museums, and other buildings. Cables have excellent fire resistance and insulation performance; Low smoke and halogen-free performance, the product is easy to bend and easy to install.
Model: WD-RTTWY, WD-RTTYZ
Rated voltage (kV): 0.6/1
Main use: Used as a power transmission line for fire protection systems in high-rise buildings, underground buildings, hospitals, schools, business centers, department stores, museums, and other buildings. Cables have excellent fire resistance and impact resistance; The length of a single cable is long, reducing cable joints and improving the reliability of system operation.
Model: RTTW, RTTZ
Rated voltage (kV): 0.6/1
Main use: Used as a power transmission line for fire protection systems in high-rise buildings, underground buildings, hospitals, schools, business centers, department stores, museums, and other buildings. Cables have excellent fire resistance and impact resistance; The length of a single cable is long, reducing cable joints and improving the reliability of system operation.
Model: WDZ * - YJLY33
Rated voltage (kV): 6-35
Main use: Fixed laying. Suitable for buildings with high fire safety requirements such as high-rise buildings and important public places