Nuclear power plant cables
Third generation nuclear power AP1000 low smoke halogen-free flame-retardant control cable outside the shell

model: ANHKEJ、ANHKEJP    

Rated voltage (kV): 0.6/1

Main use: This product is suitable for control systems with voltage levels of 0.6/1kV and below outside the safety shell of third-generation AP1000 nuclear power plants.


Low smoke, halogen-free, flame-retardant low-voltage power cables inside the shell of third-generation nuclear power plant AP1000

model: ASHLEJ、ASHLEJGP、ASHLEJG、ASHLEJP

Rated voltage (kV): 0.6/1

Main use: This product is suitable for the 0.6/1kV power transmission system inside the containment of third-generation AP1000 nuclear power plants.


1E class nickel chromium alloy (positive electrode) - nickel silicon alloy (negative electrode) conductor for nuclear power plants, ethylene propylene insulated copper wire braided total shielding thermosetting sheath, low smoke halogen-free flame retardant thermocouple compensation cable

Model: HBKXEJGP-K1

Rated voltage (kV): 0.3/0.5

Main use: This product is suitable for connecting sensors and electrical cabinets, computers, and data processing systems in the internal control system of nuclear power plant nuclear island reactor buildings.


1E grade copper (positive electrode) - copper nickel alloy (negative electrode) conductor for nuclear power plants, ethylene propylene insulated copper wire braided total shielding thermosetting sheath, low smoke halogen-free flame retardant thermocouple compensation cable

Model: HBKCBEJGP-K1

Rated voltage (kV): 0.3/0.5

Main use: This product is suitable for connecting sensors and electrical cabinets, computers, and data processing systems in the internal control system of nuclear power plant nuclear island reactor buildings.


1E class aluminum core ethylene propylene insulated thermosetting sheathed low smoke halogen-free flame-retardant medium voltage power cables for nuclear power plants

Model: HLELJ-K1

Rated voltage (kV): 6/10

Main use: This product is suitable for power transmission and distribution systems with a rated voltage of 6/10kV inside the safety shell of nuclear island reactors in nuclear power plants.


1E level cross-linked polyolefin insulated aluminum plastic composite tape group shielding, copper wire braided total shielding thermoplastic sheath low smoke halogen-free flame-retardant instrument cable for nuclear power plants

Model: HYYJAYGP-K3

Rated voltage (kV): 0.3/0.5

Main use: This product is suitable for connecting thermocouples, recorders, computers, and data processing systems in the external control system of nuclear power plant nuclear island reactor buildings.


1E grade copper (positive electrode) - copper nickel alloy (negative electrode) conductor for nuclear power plants, ethylene propylene insulated copper wire braided total shielding thermoplastic sheath, low smoke halogen-free flame retardant thermocouple compensation cable

Model: HBKCBEYGP-K3

Rated voltage (kV): 0.3/0.5

Main use: This product is suitable for connecting external control system sensors, electrical cabinets, computers, and data processing systems in nuclear power plant nuclear island reactor buildings.


1E grade nickel chromium alloy (positive electrode) - nickel silicon alloy (negative electrode) conductor cross-linked polyolefin insulated copper wire braided total shielding thermoplastic sheath low smoke halogen-free flame retardant thermocouple compensation cable for nuclear power plants

Model: HBKXYJYGP-K3

Rated voltage (kV): 0.3/0.5

Main use: This product is suitable for connecting external control system sensors, electrical cabinets, computers, and data processing systems in nuclear power plant nuclear island reactor buildings.


Non 1E grade cross-linked polyethylene insulated copper wire braided, overall shielded steel tape armored thermoplastic sheathed low smoke and halogen-free flame retardant compensation cables for nuclear power plants

model: WDZ-BKXYJP2YGP23 WDZ-BEXYJP2YGP23 WDZ-BTXYJP2YGP23

Rated voltage (kV): 0.3/0.5

Main use: Compensation cables are suitable for connecting sensors, electrical cabinets, computers, and data processing systems in control systems within the conventional island and BOP scope of nuclear power plants.


Low smoke and halogen-free flame-retardant medium voltage power cables with non 1E copper core cross-linked polyethylene insulation and thermoplastic sheath for nuclear power plants

Model: WDZ-YJY